services
We are one of the reputed names engaged in providing Installation Services to the customers. These services are rendered by a team of skilled professionals, with adherence to all the safety measures
Maintenance contract
There are many variations of passages of Lorem Ipsum available, but the majority have suffered alteration in some form, by injected humour, or randomised wordsServices Offered:
Before the start of AMC we survey the plant & existing install base of automation systems. Under this contract AAPL undertakes the following services:
1. Routine check for Healthiness of the installed PLC hardware and HMI software.
2. Study the history of alarms & events to offer you changes in Software and Hardware to obtain better system stability.
3. Checking Healthiness of existing SCADA machine including virus check.
4. Checking Panel Wiring, Power Supplies, Earth Pits.
5. Checking Activation, updates of Software Licenses & firmware which are within warranty.
6. Taking backup of Data, Software & logic.
7. Minor Rectifications in the software can be carried out as and when required.
Annual Preventive maintenance and Services Contract is available on an as-needed, scheduled, or full-time basis. we help you meet your specific needs throughout the lifecycle of your maintenance strategy.
& Validation of Automation system
We provide FDA validation service for 21 CFR part 11 documentation & system engineering as per GAMP regulations. The following elements shall be taken into consideration when developing a (21 CFR Part 11) compliant system.Designing Documents:
1. Instruments Index
2.Instruments Hook Drawing
3.Bill of Material
4.PLC/DCS Architecture
5.I/O Allocation
6.Panel GA Drawing
7.Panel Wiring Drawing
8.Load Calculation
Validation Documents:
1.Quality & Project Plan
2.User Requirement specification (URS)
3.Functional Design Specification (FDS)
4.Traceability Matrix Between URS and GDS
5.Software Design Specification (SDS)
6.Hardware Design Specification (HDS)
7.Risk Analysis
8.Factory Acceptance Test(FAT)
9.Installation Qualification Protocol
10.Traceability Matrix Between DDS and IQP
11.Operational Qualification Protocol
12.Traceability Matrix Between IQP and OQP
13.Performance Qualification (PQ)
Commissioning
1. Supervision of erection of panel , pre-checking test before panel power on, checking power sources within the panel ,earthling.2. Pre Commissioning Activity.( Panel IO testing, loop checking from panel to field as per final IO list).
3. Commissioning of project as per process description.(On site modification required in SCADA & Logic as per site requirement)
4. Project Handover reports.
Calibration
1.We providing the Calibration services for the Instruments i.e. Gauges , Transmitters , Detectors , Analyzers . We are having the Master instruments in wide ranges with NABL approved.
2.We are having skilled person for the calibration of the Various instruments who is qualified by the NABL approved agencies .
3.We are providing the Calibration services on our works as well as site .
/DCS Trouble Shooting
We are expert in trouble shooting of the PLC / DCS system, PLC / DCS logic program and SCADA system trouble shooting on Rockwell Platform, Instruments Trouble shooting including maintenance and Programming of Indicators / Controller .